Стандарты и Директивыand
Общая цель наших менеджеров и служб - предложить надежную, устойчивую, высокопроизводительную продукцию, соответствующую нормативным требованиям и/или стандартам каждой территории, где она используется.
EN352 : Exigences of safety and tests.
• EN352-1 : the ear-muff s.
• EN352-2 : the earplugs.
• EN352-3 : the adjustable head defenders for the safety helmets.
• EN352-4 : Noise cancelling headphones with level dependent attenuation.
• EN352-6 : Earmuff s with electrical audio input.
• EN352-8 : Audio enabled earmuff s. These standards establish requirements with regards to the manufacture, the design, performances and test methods.
They stipulate the putting at disposal relative to the characteristics.
Electrically insulating helmets for use near energised equipment not exceeding 1000 VAC or 1500 VDC (appliance class 0).
Used simultaneously with other electrically insulating protective equipment, these helmets prevent dangerous currents passing through to the person's head.
These optional electrical insulation tests are more stringent than the EN397 and they complement them. (2 triangle marking, Class 0).
Requirements for chemical protection clothing with liquid-tight (type 3) or spray-tight (type 4) connections, including items providing only partial body protection (types PB [3] and PB [4]).
This standard sets out the minimum requirements for the following types of limited use and reuseable chemical protective clothing:
- Clothing protecting the full body with liquid-tight connections between the various clothing parts (Type 3: liquid-tight clothing) ;
- Clothing protecting the full body with spray-tight connections between the various clothing parts (Type 4: spray-tight clothing) ;
Note: These standards were formerly entitled EN1512 (Type 4) and EN1511 (Type 3).
STANDARDS | TYPE | CHEMICAL PROTECTION |
EN13034 | 6 | Against splashes |
EN ISO 13982-1 | 5 | Against dust (asbestos) |
EN14605 | 4 | Against mists |
EN14605 | 3 | Against sprays |
TESTS | |||||
General performance | Tests & Specific performances | Level of protection | |||
3a | 4a | 5 | 6a | ||
Performance requirements for the whole garment |
Internal pressure | - | - | - | - |
Leak to interior | - | - | X | - | |
Penetration by a jet of liquid | X | - | - | - | |
Penetration by a spray (liquid spraying) | - | X | - | - | |
Against solid particles | - | - | X | - | |
Penetration by a spray (light spraying) | - | - | - | X | |
Performance requirements for seams and joints |
Mechanical resistance | X | X | X | X |
Resistance to permeation and penetration by liquids | X | X | - | - | |
Performance requirements for the constituent materials of the garment |
Abrasion / Tearing / Perforation | X | X | X | X |
Resistance to tensile strength | X | X | - | X | |
Resistance to cracking by bending | X | X | X | - | |
Resistance to cracking by bending at -30°C | X optional |
X optional |
- | - | |
Resistance to pemeation by liquids | X | X | - | - | |
Resistance to penetration by liquids |
- | - | - | X | |
Repulsion to liquids | - | - | - | X |
a - When the protective equipment only protects certain parts of the body (torso, arms, legs), only the performance requirements for the materials making up the garment are required required (types 6, 4 and 3).
PROTECTION AGAINST HEAT AND FLAME
Protection against heat and flame. This standard specifies the performance requirements of materials and protective clothing against heat and flames. They apply to clothing made of soft material, designed to protect the human body except the hands against heat and/ or flame.
Tested are:
Test | Code | Performances |
Limited flame spread | A | A1 and/or A2 |
Convective heat | B | B1 to B3 |
Radiant heat | C | C1 to C4 |
Molten aluminium splash | D | D1 to D3 |
Molten metal splash | E | E1 to E3 |
Contact heat | F | F1 to F3 |
MAIVE2 | |
|
EN ISO 11612 |
A1 A2 B1 C1 E3 F1 |